Plastic Pipes Conference Association # 2021 Amsterdam
Sultan Alkendi, Mohamed Jaber, Ahmed Atef Helal
The current push to reduce governmental energy subsidies has moved the need to adapt utility gas distribution networks toward the top of Middle Eastern governmental near-term agendas. Egypt is at the forefront of this push towards gasification. The United Arab Emirates has started on the path towards gasification with large-scale projects underway, and the Kingdom of Saudi Arabia will be quick to follow. This has presented opportunities for the regional plastic pipe industry, as well as some challenges specific to the use of plastic pipes in the region.
The specification of colored pre-compounded pipes and fittings, manufactured using PE100+ listed materials for natural gas utility distribution in Emirate of Abu Dhabi by the Abu Dhabi Quality and Conformity Council, QCC, has greatly elevated the quality requirements of plastic pipes used in this gasification effort. The specification of PE100 and PE80 pipes and fittings for natural gas utility distribution networks will also help future growth in this industry regionally. National standards and specifications have not yet been put into place, utilities rely on international standards, including ISO, GIS, and industrial standards.
The major challenge faced by gas utilities when using plastic pipes, PE100, for natural gas utility distribution in the region is high ground temperatures. International standards define de-rating factors for elevated ground temperatures. As per Abu Dhabi National Oil Company for Distribution, ADNOC Distribution, specifications MOP is typically reduced to 4 barg (refer to Table 2) to maintain a design life time of 50 years [1]. This de-rating limits the operating pressures of gas distribution networks, therefore limiting the technical and economic value that plastic pipes can add to the utilities’ gas network.
Related papers
Author(s) : James F. Mason, Akshay Ponda, Hermann van Laak, Tobias Bauer
The long-term strength of unplasticized polyamide 12 (PA-U12) has been characterized using standard methods for plastic pressure pipe during the qualification process for use in buried piping systems for natural gas delivery operating at low ambient temperatures, usually less than 20 to 30°C at pressures...
Author(s) : Norbert Jansen
A practical requirement of temperature resistance of minimum 50 years at 70°C was established for the extra high voltage (EHV) corridor projects in Germany. Experts have debated what tests are best suited to prove the suitability of a pipe resin for cable protection pipes which may be installed hastily and under...
Author(s) : Jiyong Park, JaeHyuck Han, YoungGu Kim, Eunjin Park
This study investigates the influence of various parameters on polymer design to determine the slow crack growth. HDPE(High Density Polyethylene) materials with different molecular weight distribution and comonomer content for PE100-RC pipe were investigated with cracked round bar test. The cracked round bar test...
Author(s) : Rafael A. García-Muñoz, Rafael Juan, Mónica de la Cruz, Beatriz Paredes, Carlos Domínguez
Plastics are widely used in various industries, resulting in the generation of significant amounts of plastic waste, which causes environmental and economic problems. Although mechanical recycling is the most commonly employed technology, the resulting recyclates often suffer from degradation and contamination. This...
Author(s) : Peter Youssef, Sultan Alkendi, Hussein Basha
Bahr El-Baqar Water Treatment Plant, produces 2 billion m3 per year, introduces a sustainable solution for environmental pollution recovery and irrigation water source (via recycling the water of Bahr El- Baqar drain); whereas it protects the environment and generates water to support the cultivation of 4000 km2 in...
Author(s) : Norbert Jansen, Andrew Wedgner, Rainer Kloth
PE100+ Association(client) has sponsored a technical investigation to define the permeation rate of hydrogen through polyethylene pipes at an external expert laboratory. Four different types of PE pipe materials in the same pipe size and SDR17 have been evaluated at 3 different target temperatures 8°C, 14°C and 20°C,...
Author(s) : Ali M Alghamdi, Recep Yaldiz, Faisal Almana, Yousof Ghazzawi, Abdul Rahim Arafath, Ratnesh Khandelwal, Azzedine Kioul, Turki Al-Shahrani, Salem Al-Anazi, Sarfraz Abbasi, Mohammed Aljasser, Parthipan B, Kavya A, Harm Caelers
Reinforced thermoplastic pipes (RTPs) are multilayer structured pipes reinforced with high-strength materials such as fibers (glass, aramid, or carbon fibers). RTPs are used to transport highly corrosive mediums at elevated pressures and temperatures. An example of that is the use of RTP in the Oil & Gas industry to...
Author(s) : Andrew Wedgner, Robin Bresser
PE100 pipes are the most widely used material for the installation, rehabilitation and replacement of pressure pipes for water and gas supply and for pressure sewers. Such pipes can be installed using a broad range of trenchless technologies and hence the selection of the most appropriate method and identification of...
Author(s) : Donald Swen, Leanne Pichay, Nicholas Vallin, Alice Wu, Jim Johnston
In the rural commune of Ait Bayoud, Morocco, two of the most remote villages in the area, Ilguiloda and Izgouaren, live with water scarcity. To meet their water needs, women and children walk several kilometers to the nearest spring each day, often multiple times a day. Consequently, children cannot attend school...
Author(s) : James F. Mason, Akshay Ponda, Hermann van Laak, Buc Slay
The effects of liquid hydrocarbons on long term strength of pipe grade thermoplastic resins is an important consideration when designing pressure pipe for use in the oil and gas industry. There is an extensive body of work going back several decades descri bing these effects for pipe grade polyethylenes, and all...
Author(s) : S. Nestelberger, J. Cheng
The Point Load Test (PLT) [ 1, 2] was designed to simulate the SCG (slow crack growth) failure initiated by a rock pressing into the exterior wall of a polymer pipe. Today’s PE materials sustain long PLT testing times, due to its high SCG resistance design. Consequently, an accelerated “PLT+” with the support...
Author(s) : Dr. Holger Brüning, Serge Hascoët, Yann Delanne, Didier Nozahic, Jawdat Mansour, José Santana
RTE operates, maintains and develops the French electricity network, including the High and very High Voltage cable lines. Their network is the largest in Europe and includes over 6400 km of underground HV links operated in 2018. The company is modernizing and developing its network by investing 1.5 billion euros per...
Author(s) : Prashant Nikhade, Farraj Tashman
In the Middle East and India, PE pipes have expanded their applications in a big way for water supply, industrial effluents, corrosive chemical transportation, slurry transportation, city gas distribution networks and agriculture irrigation purposes over ductile iron, cast iron and other conventional pipes. PE...
Author(s) : Stephan Kneck, Henrik Iskov
It has become ever clearer that the resources of natural gas are an energy source, which will be less important in the future due to limitations in use of natural reserves. In order to prepare for the future the gas industry is looking at the alternative fuel gases, one such fuel gas is hydrogen. In order to prepare...
Author(s) : Suleyman Deveci, Nisha Preschilla, Sulistiyanto Nugroho, Birkan Eryigit
Carbon black (CB) has been used as a perfect and the cheapest solution to prevent photo degradation of polyethylene against UV light exposure. The effect of carbon black on the mechanical properties of polyethylene pipes was studied extensively, but only on well dispersed and distributed carbon black...
Author(s) : Hermann van Laak, Jan Heimink, Mario Messiha, Andreas Frank, Christoph Bruckner, Thomas Kratochvilla
For high pressure pipes above maximum operation pressure of 10 bar, this paper emphasizes PA-U12 as the easy to install alternative to steel. It underlines the superb performance of PA-U12 pipes for alternative installation techniques without need for a separate mechanical protection. An unplasticized polyamide 12...
Author(s) : M. Boerakker, S. van Mierloo, D. v. Beek, R. Schipper, P. Voets, M. Soliman, K. Jacobson, D. Lukes, B. Rabaud, F. Zraick
HDPE pipes are used for standard pressurized water pipes, offering an excellent solution for safe transport of (drinking) water. The HDPE pipe market is growing globally. Especially in countries that suffer from water scarcity, surface water and water from rivers have to be used for drinking water supply. To...
Author(s) : Liang Yu, Akshay Ponda, Dane Chang
Following the development of US shale oil and gas production since 2007, the demand for thermoplastic pipes with better corrosion resistance, and lower installation and operation cost than carbon steel pipe, has been growing significantly. Nylon 12 has been qualified for hydrocarbon transportation in offshore...
Author(s) : Mario Messiha, Andreas Frank, Isabelle J. Berger, Jan Heimink, Hermann van Laak, Florian Arbeiter, Gerald Pinter
Since the last decade polyamide 12 (PA12) has been successfully introduced as material for SDR 11 gas piping systems up to 18 bar, representing itself as an attractive alternative to steel pipes for high-pressure applications. Practical experience has confirmed that beside the higher strength, PA12 pipe grades ...
Author(s) : Ryosuke Nagahisa, Shinichi Katoh
We investigated the possibility of using a greaseless polyethylene (PE) ball valve by applying a coating on it to improve the valve’s robustness. In order to verify the valve’s operability, we performed initial-operating-torque, abrasion, and dust tests on both grease-applied and coatingapplied ball valves. These...