Plastic Pipes Conference Association # 2021 Amsterdam
Drew Mueller, Peter Dyke
HDPE Pipe holds a dominant position in several markets in North America: natural gas distribution, oil patch, mining, landfill and geothermal. So why are polyethylene’s municipal water and wastewater market shares so much lower than these other industries? How has the polyethylene industry been successful in growing HDPE’s market share in municipal water and wastewater? In North America, PE industry leaders joined forces to create a trade association with the singular mission of promoting HDPE pipe into municipal markets where the traditional metals have a strong presence. In the last nine years, PE’s market share in municipal water and wastewater has grown from two percent to ten percent of this industry. In that time, the industry’s approach to municipal business has matured thanks to an examination of successes and failures; polyethylene manufacturers and distributers now know how to connect with municipal leadership, what messages are most compelling, what common hurdles the new polyethylene user must overcome, and how to battle the heavy resistance put up by entrenched, legacy pipe products. An examination of the history of plastic pipe, coupled with a thorough exploration of the five phases of municipal adoption will shed light on why polyethylene appears to be a late bloomer when it comes to municipal use of plastic piping materials. By fully understanding how HDPE fits in to the evolution of piping materials most US cities find themselves entrenched in, the experienced HDPE manufacturer or distributer will be better prepared to target specific municipalities with strategies that complement that particular community’s infrastructure history and needs. Perhaps other geographic markets could benefit from the trials and the maturation of this North America’s trade association.
Related papers
Author(s) : A. Taraiya, P. Degenhart, M. Soliman, M. Boerakker, R. Handstanger, R. Kleppinger
Since the introduction of polyolefins for pressure pipes, continuous improvements have been made to meet ever-higher demands on their performance and to expand their application window beyond their original scope, mostly based on new resin formulations. Today, we also continue to push the limit to provide better...
Author(s) : Derek Muckle
A technical program has been undertaken to provide evidence on the suitability of polyethylene pipe and fitting systems for the distribution of hydrogen fuel gas. The underlying principle has been to evaluate material in the form of a pipe and to consider the performance of the pipe and of the welded jointing systems...
Author(s) : Lei Wang, Guozhi Xu, Qiaoping Qiu, Weihua Lu, Yanwang Han
PP-R (random copolymerized polypropylene) has been widely used in hot and cold water systems. However, the standard PP-R pipes have the disadvantages of a large high-temperature thermal expansion coefficient, an insufficient notched impact strength, and a low temperature and pressure resistance. In this paper, a new...
Author(s) : Donald Swen, Leanne Pichay, Nicholas Vallin, Alice Wu, Jim Johnston
In the rural commune of Ait Bayoud, Morocco, two of the most remote villages in the area, Ilguiloda and Izgouaren, live with water scarcity. To meet their water needs, women and children walk several kilometers to the nearest spring each day, often multiple times a day. Consequently, children cannot attend school...
Author(s) : Ilija Radeljic, Ebbe Smith
HDPE pipe can be relatively easily scratched during the manipulation on the site, which is especially true for the marine pipelines. Installing the scratched marine pipe with the S bend method presents a risk and repair methods are usually performed. Currently, there is no standard defining the repair procedure, in...
Author(s) : Bruce Mowry, PhD, P.E., Brian Dorwart, P.G., P.E., David Mancini, Bryan Fletcher, Roger Williams, P.E., Rene Brito, EIT, Arnelio Alfonso, P.E .
The City of Miami Beach owns and operates a 54-inch sanitary sewage PCCP force main (FM) that was built in 1977. This FM is the only transmission pipeline for conveying about 22 million gallons per day (MGD) of raw sewage to the wastewater treatment plant. In 2012, the City identified structural deficiencies in the...
Author(s) : Tom Stewart, Richard Hicks, Patrick Vibien, Lance MacNevin
Arguably, broadband technologies have become as vital to society as water delivery, waste removal and energy distribution. However, the role of plastic conduit in broadband is often overlooked within the piping industry and society in general. HDPE conduit is an essential component to the build -out of 5G cell...
Author(s) : Joe Babcanec, P.E., Dan Currence, P.E.
The newly released Drainage Handbook provides complete guidance on corrugated polyolefin pipe. Perhaps the biggest contribution this new handbook makes to the advancement of both HDPE and PP corrugated plastic pipe is the design procedure presented. The design procedure reflects the industry’s recommended practice...
Author(s) : Paul J. Freudenthaler, Joerg Fischer, Mathias Eder, Reinhold W. Lang
For controlled water disinfection, typically chlorine is used and preliminary studies demonstrate its aging and crack growth acceleration effects on polyolefin pipe materials [1, 2]. Although the use of recycled plastics is not prohibited in some ISO standards for polyolefin piping systems [3–5], only small amounts...
Author(s) : James F. Mason, Akshay Ponda, Hermann van Laak, Buc Slay
The effects of liquid hydrocarbons on long term strength of pipe grade thermoplastic resins is an important consideration when designing pressure pipe for use in the oil and gas industry. There is an extensive body of work going back several decades descri bing these effects for pipe grade polyethylenes, and all...
Author(s) : Ernst van der Stok
For PE 100-RC, two tests are still under development for pipes: the point load test (PLT) and the accelerated notch pipe test (aNPT). The PLT was developed by a project group consisting of manufacturers and end users. The PLT determines the resistance to point loads as they can occur in practice. An earlier study...
Author(s) : S. Nestelberger, J. Cheng
The Point Load Test (PLT) [ 1, 2] was designed to simulate the SCG (slow crack growth) failure initiated by a rock pressing into the exterior wall of a polymer pipe. Today’s PE materials sustain long PLT testing times, due to its high SCG resistance design. Consequently, an accelerated “PLT+” with the support...
Author(s) : Amster Howard
Flowable fill is used for many applications, but mainly for pipe trench embedment and backfill. There are three ways that using flowable fill can be kind to the environment. Because flowable fill is self-leveling and has a strength greater than the native soil, the trench cross section can be minimized. This means...
Author(s) : Gerald Pinter, Johannes Wiener, Florian Arbeiter, Abhishek Tiwari, Otmar Kolednik
For pipe applications, catastrophic failure due to crack growth has to be prevented by all means. Techniques to develop new and even tougher pipe materials are explored in this contribution. The aim is to create a multi-layer architecture, that exhibits high toughness as well as damage tolerance towards sharp notches....
Author(s) : Greg Scoby, PE
This paper will detail the steps taken during adoption of HDPE for potable water systems improvements including material justification, creation of related specifications, investigation of available piping components, qualification of contractors and the construction/inspection of related systems. The City of...
Author(s) : Christian Schalich
Plastic pipes for infrastructure and building applications are precisely specified with regards to wall thickness and diameter. Pipe manufacturers use different measuring methods in order to ensure the required dimensional accuracy and maintain a constant high quality. This paper introduces a measuring system based on...
Author(s) : Mitsuaki Tokiyoshi, Yuichi Shibao, Yoshitaka Watanabe, Takeshi Yoshioka, Takashi Oka, Kohei Sasaki
It was common to use those pipelines for Steel in Japan. However Steel pipes have the long standing problems that it has been needed maintenance costs for rust prevention and antifouling property. Therefore it had been carried out the project that large diameter polyethylene pipeline applied for circulating water...
Author(s) : Eng. Grigorios Vigellis, Eng. Mohamed Hageb
Continuous development and innovation in the production of plastic pipes made by high density polyethylene (HDPE) has enabled the industry to produce much larger diameter systems than ever believed possible. The enablers for production of such large plastic pipes are three main pillars: continuous innovation...
Author(s) : Suleyman Deveci, Nisha Preschilla, Sulistiyanto Nugroho, Birkan Eryigit
Carbon black (CB) has been used as a perfect and the cheapest solution to prevent photo degradation of polyethylene against UV light exposure. The effect of carbon black on the mechanical properties of polyethylene pipes was studied extensively, but only on well dispersed and distributed carbon black...
Author(s) : White G. Jee, Wes Long, Marcello Russo
In 2018, the North American HDPE pressure pipe market experienced unprecedented demand and growth especially in the region of the Permian basin in west Texas. 1 As aninnovative means of increasing HDPE pipe supply in this region, the first modular mobile extrusion plant was moved to Pecos, TX. Using custom designed...