Plastic Pipes Conference Association # 2014 Chicago
Seonghee Kil, Jeongrock Kwon, Keebong Yoon
Non destructive evaluation(NDE) of polyethylene electrofusion socket joint could be a kind of methods to support the elelctro fusion processes and procedures. Defects example of lack of fusion, porosity, foreign material, inserting defect and dislocation of heating wires could be detected by using phase array ultrasonic imaging methods. However, in some cases, joint had been failed for other reasons except above mentioned defects, and this defect does not seem to be a certain shape. This paper studies about detecting results by using phase array ultrasonic imaging methods of improper fusion for polyethylene electrofusion joint and comparing those results with crush test results of same test specimens. Density of test material for detecting of improper fusion was 0.939g/cm3, and outside diameter of pipe was 225mm, SDR 11. 17 test specimens had been prepared by changing proper heating time from 0% to 130%. In addition to 17 test specimens, one specimen had been prepared by attaching the soil in the fusion zone of the pipe, another specimen had been prepared with two defects which were artificially made with paper, and other specimen had not been scrapped on the surface of the pipe and had been inserted into the socket and electrofused. Therefore, total 20 test specimens had been made. By using phase array ultrasonic imaging methods, heat affected zone was detected. Also, the distance between heating wires and heat affected zone was measured. The distance between heating wires and heat affected zone was varied by heating times. To compare this NDE result with destructive test, crush test was conducted according to ISO 13955(crush decohesion test) 7.2(electrofusion sockets). The distance from the 1st heating wire to the last one was 50mm, and tests were carried out three times. Brittle failure length was measured in the fusion plane at the outer edge of the fitting parallel of the pipe axis. From this study, improper fusion could be detected by using phase array ultrasonic imaging methods and measuring the distance from heating wires to indication of heat affected zone. The distance between heat affected zone and heating wires was varied by heating times. No scraping, defect inclusion and soil inclusion specimen were completely separated. Specimens applied heating times from 10 to 30% of proper heating time were separated also.
Related papers
Author(s) : Xin Zhou, Abdullah Saber, Shuqiang Wang, Huilong Chen
PE-RT II (PE100 classification) is designed >50 years lifespan at elevated temperature which aims to the growing demands on the applications of hot water and other industrial applications. District heating is a growing market in Greater China. However, the conventional pipes have serious corrosion issue in this...
Author(s) : Yi Zhong, Qianshi Ma, Haihua Yu
BSTRACT The residential district adopts central heating for low temperature radiators system. Due to the disrepair of the secondary heating pipe network that pipe from heat exchange station to user entrance, the running, leaking, dripping and leakage are serious, and the accidents occur frequently. The heat...
Author(s) : Amster Howard
This paper explores the use of a composite soil stiffness as a valuable design tool to consider when a pipeline traverses through poor soil conditions. Thermoplastic pipe are flexible pipe and require good soil support at the sides of the pipe to minimize deflection. However, sometimes the trench walls are weak soils...
Author(s) : Sunwoong Choi, Robert Stakenborghs , Pyeongan Lee, Byoungho Choi
This work developed a hydro-axial tension (HAT) test as a whole pipe axial tensile test and applied to evaluate the polyethylene (PE) pipe and fusion joints containing various flaws. HAT test was designed to utilize hydrostatic pressure to cause axial tension in pipes. The experimental and numerical analysis was...
Author(s) : Carine Lacroix, Philippe Louvel, Danielle Mark, Dominique Gueugnaut
A test program was carried out on two Polyamide resins, Polyamide 11 (PA11) and Polyamide 12 (PA12), both certified for gas networks. Polyamide’s advantage lies in its implementation, similar to that of polyethylene, and its properties allowing it to operate at up to 18 bar for gas, all other conditions being equal....
Author(s) : Nayib Joussef, Chris Zenthoefer, Sergio Vaccaro
Butt fusion of HDPE pipe has long been shown to be an extremely beneficial process in producing leak-free, monolithic piping systems. Continued growth of the Chilean mining sector has necessitated a substantial increase in polyethylene pipe sizes and wall thicknesses, with diameters well beyond 630 mm up to 2m...
Author(s) : Chris Greggs
Much has been done to improve the quality and efficiency of HDPE pipe installations over the years. Now, a totally new concept for fusion where the machine meets the pipe where it lays to improve worksite safety, boost jobsite efficiency, and minimize the amount of time spent between fusions has been developed. This...
Author(s) : Giorgio Tabanelli
In plastic pipes for the distribution of pressurized water, the jointing technique using a Rieber-type socket is mainly used for PVC-U pipes. In such a socket, the gasket is integral part of the socket wall, and is no longer removable or even replaceable. On the other hand, in Molecularly Oriented Polyvinyl Chloride...
Author(s) : Chris Ampfer, Gene Palermo, Ernest & Oren Lever
This paper looks at the origin of the 10% allowable scratch depth rule for polyethylene (PE) pressure pipe developed in 1971 and research that has been performed over the years since its inception to determine the validity of this rule. The 10% rule has been used by natural gas pipeline operators since the 1970’s to...
Author(s) : Mike Troughton, Amir Khamsehnezhad, Changyi Yu
When butt fusion welding polyethylene (PE) pipes in the field, it is often specified that the pipes must undergo fusibility testing in all combinations of suppliers, diameters and thicknesses before being fused in production. This is a very onerous and expensive task, but must be carried out to ensure that the PE...
Author(s) : Greg Scoby, PE
This paper will detail the steps taken during adoption of HDPE for potable water systems improvements including material justification, creation of related specifications, investigation of available piping components, qualification of contractors and the construction/inspection of related systems. The City of...
Author(s) : M. Eckes & Dr. B. Baudrit, Dr. M. Troughton & D. Wylie, H. van Laak & J. Fritz
Unplasticized polyamide 12 (PA-U12) is increasingly being used in pipe applications, especially in the gas sector. However, the material behavior in the usual quality tests for pipe welds has not yet been thoroughly investigated. For this reason, two research institutes, worked in cooperation with a manufacturer of...
Author(s) : Suleyman Deveci, Nisha Preschilla, Sulistiyanto Nugroho, Birkan Eryigit
Carbon black (CB) has been used as a perfect and the cheapest solution to prevent photo degradation of polyethylene against UV light exposure. The effect of carbon black on the mechanical properties of polyethylene pipes was studied extensively, but only on well dispersed and distributed carbon black...
Author(s) : Alex Stolarz, Klaus Grønnegaard Lauridsen
Low temperature District Heating – COOL DH – addresses the challenges of the upcoming decades in the energy sector for new housing developments. Energy efficiency is an important aspect of modern building construction. Improved building insulation and other technologies result in lower heat demand and enable new...
Author(s) : Steve Sandstrum, Chris Ziu
The market for high performance polypropylene (PP) piping systems in North America continues to evolve. Generally, PP piping systems have performed exceptionally well in a variety of challenging HVAC, industrial and plumbing applications. As a result, the engineering community in North America is embracing higher...
Author(s) : Ulrich Schulte, Dr. -Ing. Joachim Hessel
In order to protect the Austrian lakes effectively against the discharge of effluent, a 13 km long pressure pipeline made of high density polyethylene was laid on the bottom of Lake Ossiach back in 1971. The DN355 to DN200 pipes were produced from a first generation HDPE-compound. The classification would have been...
Author(s) : Amster Howard
Deeper pipe burial, less expensive and environmentally friendly backfill, uniform language for contractors and inspectors, simplified installations for smaller pipe, and allowable construction in poor soil conditions are highlights in the latest edition of AWWA M55 and all benefit the users of HDPE pressure pipe. This...
Author(s) : Jörg Wermelinger, Sunwoong Choi
In the development of an international standard on non-destructive test for polyethylene electrofusion socket (EF) joints, the inspection capability of the phased array ultrasonic test (PAUT) in assessing flaws in the joints was needed to establish procedure qualification of the test method. For this, a worldwide...
Author(s) : Nolene Byrne, Rasike De Silva, Keith Lenghaus, Tim Hilditch
Plastic pipes have been utilized in the Australian gas distribution network since the early 1970s. The most common plastic type found in Australia is polyethylene (PE), although nylon is extensively used in New South Wales. Early installation of PE pipe was completed using the first generation high density type PE50...
Author(s) : Davidovski Zoran
To get a deeper insight in why plastic pipes systems in some cases are deselected by designers, installers and users, European Plastics Pipes and Fittings Association (TEPPFA) initiated a research including interviews in four pilot countries: Poland, France, Germany and the UK. The first phase was concentrating on...